Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 182
Filtrar
2.
Nitric Oxide ; 146: 24-30, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38521488

RESUMO

BACKGROUND: Cardiopulmonary bypass (CPB) is associated with intravascular hemolysis which depletes endogenous nitric oxide (NO). The impact of hemolysis on pulmonary arterial compliance (PAC) and right ventricular systolic function has not been explored yet. We hypothesized that decreased NO availability is associated with worse PAC and right ventricular systolic function after CPB. METHODS: This is a secondary analysis of an observational cohort study in patients undergoing cardiac surgery with CPB at Massachusetts General Hospital, USA (2014-2015). We assessed PAC (stroke volume/pulmonary artery pulse pressure ratio), and right ventricular function index (RVFI) (systolic pulmonary arterial pressure/cardiac output), as well as NO consumption at 15 min, 4 h and 12 h after CPB. Patients were stratified by CPB duration. Further, we assessed the association between changes in NO consumption with PAC and RVFI between 15min and 4 h after CPB. RESULTS: PAC was lowest at 15min after CPB and improved over time (n = 50). RVFI was highest -worse right ventricular function- at CPB end and gradually decreased. Changes in hemolysis, PAC and RVFI differed over time by CPB duration. PAC inversely correlated with total pulmonary resistance (TPR). TPR and PAC positively and negatively correlated with RVFI, respectively. NO consumption between 15min and 4 h after CPB correlated with changes in PAC (-0.28 ml/mmHg, 95%CI -0.49 to -0.01, p = 0.012) and RVFI (0.14 mmHg*L-1*min, 95%CI 0.10 to 0.18, p < 0.001) after multivariable adjustments. CONCLUSION: PAC and RVFI are worse at CPB end and improve over time. Depletion of endogenous NO may contribute to explain changes in PAC and RVFI after CPB.

6.
Chest ; 2024 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-38295949

RESUMO

BACKGROUND: Positive end-expiratory pressure (PEEP) can potentially modulate inspiratory effort (ΔPes), which is the major determinant of self-inflicted lung injury. RESEARCH QUESTION: Does high PEEP reduce ΔPes in patients with moderate-to-severe ARDS on assisted ventilation? STUDY DESIGN AND METHODS: Sixteen patients with Pao2/Fio2 ≤ 200 mm Hg and ΔPes ≥ 10 cm H2O underwent a randomized sequence of four ventilator settings: PEEP = 5 cm H2O or PEEP = 15 cm H2O + synchronous (pressure support ventilation [PSV]) or asynchronous (pressure-controlled intermittent mandatory ventilation [PC-IMV]) inspiratory assistance. ΔPes and respiratory system, lung, and chest wall mechanics were assessed with esophageal manometry and occlusions. PEEP-induced alveolar recruitment and overinflation, lung dynamic strain, and tidal volume distribution were assessed with electrical impedance tomography. RESULTS: ΔPes was not systematically different at high vs low PEEP (PSV: median, 20 cm H2O; range, 15-24 cm H2O vs median, 15 cm H2O; range, 13-23 cm H2O; P = .24; PC-IMV: median, 20; range, 18-23 vs median, 19; range, 17-25; P = .67, respectively). Similarly, respiratory system and transpulmonary driving pressures, tidal volume, lung/chest wall mechanics, and pendelluft extent were not different between study phases. High PEEP resulted in lower or higher ΔPes, respiratory system driving pressure, and transpulmonary driving pressure according to whether this increased or decreased respiratory system compliance (r = -0.85, P < .001; r = -0.75, P < .001; r = -0.80, P < .001, respectively). PEEP-induced changes in respiratory system compliance were driven by its lung component and were dependent on the extent of PEEP-induced alveolar overinflation (r = -0.66, P = .006). High PEEP caused variable recruitment and systematic redistribution of tidal volume toward dorsal lung regions, thereby reducing dynamic strain in ventral areas (PSV: median, 0.49; range, 0.37-0.83 vs median, 0.96; range, 0.62-1.56; P = .003; PC-IMV: median, 0.65; range, 0.42-1.31 vs median, 1.14; range, 0.79-1.52; P = .002). All results were consistent during synchronous and asynchronous inspiratory assistance. INTERPRETATION: The impact of high PEEP on ΔPes and lung stress is interindividually variable according to different effects on the respiratory system and lung compliance resulting from alveolar overinflation. High PEEP may help mitigate the risk of self-inflicted lung injury solely if it increases lung/respiratory system compliance. TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT04241874; URL: www. CLINICALTRIALS: gov.

9.
Artigo em Inglês | MEDLINE | ID: mdl-38056793

RESUMO

Ultrasound evaluation of the upper airway has emerged as an essential instrument for clinicians, offering real-time assessment that can help to guide interventions and improve patient outcomes. This review aims to provide health care providers with a practical approach to performing ultrasound evaluation of the upper airway, covering basic physics relevant to upper airway ultrasound, the identification of key anatomical structures, and elucidating its various clinical applications, such as prediction of difficult airway, confirmation of endotracheal intubation, and guidance for surgical airway procedures and airway blocks. We also discuss evidence-based training programs, limitations, and future directions of ultrasound imaging of the upper airway.

10.
Eur J Anaesthesiol ; 40(11): 805-816, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37789753

RESUMO

BACKGROUND: A protective intra-operative lung ventilation strategy has been widely recommended for laparoscopic surgery. However, there is no consensus regarding the optimal level of positive end-expiratory pressure (PEEP) and its effects during pneumoperitoneum. Electrical impedance tomography (EIT) has recently been introduced as a bedside tool to monitor lung ventilation in real-time. OBJECTIVE: We hypothesised that individually titrated EIT-PEEP adjusted to the surgical intervention would improve respiratory mechanics during and after surgery. DESIGN: Randomised controlled trial. SETTING: First Medical Centre of Chinese PLA General Hospital, Beijing. PATIENTS: Seventy-five patients undergoing robotic-assisted laparoscopic hepatobiliary and pancreatic surgery under general anaesthesia. INTERVENTIONS: Patients were randomly assigned 2 : 1 to individualised EIT-titrated PEEP (PEEPEIT; n = 50) or traditional PEEP 5 cmH2O (PEEP5 cmH2O; n = 25). The PEEPEIT group received individually titrated EIT-PEEP during pneumoperitoneum. The PEEP5 cmH2O group received PEEP of 5 cmH2O during pneumoperitoneum. MAIN OUTCOME MEASURES: The primary outcome was respiratory system compliance during laparoscopic surgery. Secondary outcomes were individualised PEEP levels, oxygenation, respiratory and haemodynamic status, and occurrence of postoperative pulmonary complications (PPCs) within 7 days. RESULTS: Compared with PEEP5 cmH2O, patients who received PEEPEIT had higher respiratory system compliance (mean values during surgery of 44.3 ±â€Š11.3 vs. 31.9 ±â€Š6.6, ml cmH2O-1; P < 0.001), lower driving pressure (11.5 ±â€Š2.1 vs. 14.0 ±â€Š2.4 cmH2O; P < 0.001), better oxygenation (mean PaO2/FiO2 427.5 ±â€Š28.6 vs. 366.8 ±â€Š36.4; P = 0.003), and less postoperative atelectasis (19.4 ±â€Š1.6 vs. 46.3 ±â€Š14.8 g of lung tissue mass; P = 0.003). Haemodynamic values did not differ significantly between the groups. No adverse effects were observed during surgery. CONCLUSION: Individualised PEEP by EIT may improve intra-operative pulmonary mechanics and oxygenation without impairing haemodynamic stability, and decrease postoperative atelectasis. TRIAL REGISTRATION: Chinese Clinical Trial Registry (www.chictr.org.cn) identifier: ChiCTR2100045166.


Assuntos
Pneumoperitônio , Atelectasia Pulmonar , Humanos , Impedância Elétrica , Pneumoperitônio/etiologia , Pulmão/diagnóstico por imagem , Respiração com Pressão Positiva/métodos , Atelectasia Pulmonar/etiologia , Atelectasia Pulmonar/prevenção & controle , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Tomografia/métodos
11.
Crit Care Explor ; 5(10): e0983, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37795456

RESUMO

OBJECTIVES: Experimental models suggest that prone position and positive end-expiratory pressure (PEEP) homogenize ventral-dorsal ventilation distribution and regional respiratory compliance. However, this response still needs confirmation on humans. Therefore, this study aimed to assess the changes in global and regional respiratory mechanics in supine and prone positions over a range of PEEP levels in acute respiratory distress syndrome (ARDS) patients. DESIGN: A prospective cohort study. PATIENTS: Twenty-two intubated patients with ARDS caused by COVID-19 pneumonia. INTERVENTIONS: Electrical impedance tomography and esophageal manometry were applied during PEEP titrations from 20 cm H2O to 6 cm H2O in supine and prone positions. MEASUREMENTS: Global respiratory system compliance (Crs), chest wall compliance, regional lung compliance, ventilation distribution in supine and prone positions. MAIN RESULTS: Compared with supine position, the maximum level of Crs changed after prone position in 59% of ARDS patients (n = 13), of which the Crs decreased in 32% (n = 7) and increased in 27% (n = 6). To reach maximum Crs after pronation, PEEP was changed in 45% of the patients by at least 4 cm H2O. After pronation, the ventilation and compliance of the dorsal region did not consistently change in the entire sample of patients, increasing specifically in a subgroup of patients who showed a positive change in Crs when transitioning from supine to prone position. These combined changes in ventilation and compliance suggest dorsal recruitment postpronation. In addition, the subgroup with increased Crs postpronation demonstrated the most pronounced difference between dorsal and ventral ventilation distribution from supine to prone position (p = 0.01), indicating heterogeneous ventilation distribution in prone position. CONCLUSIONS: Prone position modifies global respiratory compliance in most patients with ARDS. Only a subgroup of patients with a positive change in Crs postpronation presented a consistent improvement in dorsal ventilation and compliance. These data suggest that the response to pronation on global and regional mechanics can vary among ARDS patients, with some patients presenting more dorsal lung recruitment than others.

12.
Am J Respir Crit Care Med ; 208(12): 1293-1304, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37774011

RESUMO

Rationale: The effects of high-dose inhaled nitric oxide on hypoxemia in coronavirus disease (COVID-19) acute respiratory failure are unknown. Objectives: The primary outcome was the change in arterial oxygenation (PaO2/FiO2) at 48 hours. The secondary outcomes included: time to reach a PaO2/FiO2.300mmHg for at least 24 hours, the proportion of participants with a PaO2/FiO2.300mmHg at 28 days, and survival at 28 and at 90 days. Methods: Mechanically ventilated adults with COVID-19 pneumonia were enrolled in a phase II, multicenter, single-blind, randomized controlled parallel-arm trial. Participants in the intervention arm received inhaled nitric oxide at 80 ppm for 48 hours, compared with the control group receiving usual care (without placebo). Measurements and Main Results: A total of 193 participants were included in the modified intention-to-treat analysis. The mean change in PaO2/FiO2 ratio at 48 hours was 28.3mmHg in the intervention group and 21.4mmHg in the control group (mean difference, 39.1mmHg; 95% credible interval [CrI], 18.1 to 60.3). The mean time to reach a PaO2/FiO2.300mmHg in the interventional group was 8.7 days, compared with 8.4 days for the control group (mean difference, 0.44; 95% CrI, 23.63 to 4.53). At 28 days, the proportion of participants attaining a PaO2/FiO2.300mmHg was 27.7% in the inhaled nitric oxide group and 17.2% in the control subjects (risk ratio, 2.03; 95% CrI, 1.11 to 3.86). Duration of ventilation and mortality at 28 and 90 days did not differ. No serious adverse events were reported. Conclusions: The use of high-dose inhaled nitric oxide resulted in an improvement of PaO2/FiO2 at 48 hours compared with usual care in adults with acute hypoxemic respiratory failure due to COVID-19.


Assuntos
COVID-19 , Insuficiência Respiratória , Adulto , Humanos , Óxido Nítrico/uso terapêutico , COVID-19/complicações , Método Simples-Cego , Insuficiência Respiratória/tratamento farmacológico , Insuficiência Respiratória/etiologia , Respiração Artificial , Administração por Inalação
13.
Transfusion ; 63(9): 1661-1676, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37606376

RESUMO

BACKGROUND: While prior studies of platelet transfusion in critical care have focused on transfusions given, proper analysis of clinical transfusion practice also requires consideration of the decision not to transfuse. STUDY DESIGN AND METHODS: We introduce a new method to assess transfusion practice based on decision time intervals (DTIs). Each patient's intensive care (ICU) stay was segmented into a series of DTIs defined by a time interval following results of a complete blood count (CBC). We studied the presence of 17 clinical factors during each DTI whether transfusion was given or not. We used a generalized linear mixed model to assess the most influential clinical triggers for platelet transfusion. RESULTS: Among 6125 ICU patients treated between October 2016 and October 2021, we analyzed 39,745 DTIs among patients (n = 2921) who had at least one DTI with thrombocytopenia (≤150,000/µL). We found no association between platelet count and two markers of bleeding: drop in hemoglobin and chest tube drainage. We found that the majority of DTIs were associated with no platelet transfusion regardless of the platelet count; that no specific platelet value triggered transfusion; but rather that multiple clinical factors in conjunction with the platelet count influenced the decision to transfuse. DISCUSSION: DTI analysis represents a new method to assess transfusion practice that considers both transfusions given and not given, and that analyzes clinical circumstances present when decisions regarding transfusion are made. The method is easily adapted to blood components other than platelet transfusions and is easily extended to other ICU and other hospital settings.


Assuntos
Transfusão de Sangue , Transfusão de Plaquetas , Humanos , Cuidados Críticos , Plaquetas , Contagem de Plaquetas
14.
Anesthesiology ; 139(6): 815-826, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-37566686

RESUMO

BACKGROUND: Bedside electrical impedance tomography could be useful to visualize evolving pulmonary perfusion distributions when acute respiratory distress syndrome worsens or in response to ventilatory and positional therapies. In experimental acute respiratory distress syndrome, this study evaluated the agreement of electrical impedance tomography and dynamic contrast-enhanced computed tomography perfusion distributions at two injury time points and in response to increased positive end-expiratory pressure (PEEP) and prone position. METHODS: Eleven mechanically ventilated (VT 8 ml · kg-1) Yorkshire pigs (five male, six female) received bronchial hydrochloric acid (3.5 ml · kg-1) to invoke lung injury. Electrical impedance tomography and computed tomography perfusion images were obtained at 2 h (early injury) and 24 h (late injury) after injury in supine position with PEEP 5 and 10 cm H2O. In eight animals, electrical impedance tomography and computed tomography perfusion imaging were also conducted in the prone position. Electrical impedance tomography perfusion (QEIT) and computed tomography perfusion (QCT) values (as percentages of image total) were compared in eight vertical regions across injury stages, levels of PEEP, and body positions using mixed-effects linear regression. The primary outcome was agreement between QEIT and QCT, defined using limits of agreement and Pearson correlation coefficient. RESULTS: Pao2/Fio2 decreased over the course of the experiment (healthy to early injury, -253 [95% CI, -317 to -189]; early to late injury, -88 [95% CI, -151 to -24]). The limits of agreement between QEIT and QCT were -4.66% and 4.73% for the middle 50% quantile of average regional perfusion, and the correlation coefficient was 0.88 (95% CI, 0.86 to 0.90]; P < 0.001). Electrical impedance tomography and computed tomography showed similar perfusion redistributions over injury stages and in response to increased PEEP. QEIT redistributions after positional therapy underestimated QCT in ventral regions and overestimated QCT in dorsal regions. CONCLUSIONS: Electrical impedance tomography closely approximated computed tomography perfusion measures in experimental acute respiratory distress syndrome, in the supine position, over injury progression and with increased PEEP. Further validation is needed to determine the accuracy of electrical impedance tomography in measuring perfusion redistributions after positional changes.


Assuntos
Síndrome do Desconforto Respiratório , Tomografia Computadorizada por Raios X , Masculino , Feminino , Suínos , Animais , Impedância Elétrica , Síndrome do Desconforto Respiratório/terapia , Pulmão , Perfusão , Tomografia/métodos
18.
Genome Med ; 15(1): 49, 2023 07 12.
Artigo em Inglês | MEDLINE | ID: mdl-37438797

RESUMO

BACKGROUND: The gut microbiome is a critical modulator of host immunity and is linked to the immune response to respiratory viral infections. However, few studies have gone beyond describing broad compositional alterations in severe COVID-19, defined as acute respiratory or other organ failure. METHODS: We profiled 127 hospitalized patients with COVID-19 (n = 79 with severe COVID-19 and 48 with moderate) who collectively provided 241 stool samples from April 2020 to May 2021 to identify links between COVID-19 severity and gut microbial taxa, their biochemical pathways, and stool metabolites. RESULTS: Forty-eight species were associated with severe disease after accounting for antibiotic use, age, sex, and various comorbidities. These included significant in-hospital depletions of Fusicatenibacter saccharivorans and Roseburia hominis, each previously linked to post-acute COVID syndrome or "long COVID," suggesting these microbes may serve as early biomarkers for the eventual development of long COVID. A random forest classifier achieved excellent performance when tasked with classifying whether stool was obtained from patients with severe vs. moderate COVID-19, a finding that was externally validated in an independent cohort. Dedicated network analyses demonstrated fragile microbial ecology in severe disease, characterized by fracturing of clusters and reduced negative selection. We also observed shifts in predicted stool metabolite pools, implicating perturbed bile acid metabolism in severe disease. CONCLUSIONS: Here, we show that the gut microbiome differentiates individuals with a more severe disease course after infection with COVID-19 and offer several tractable and biologically plausible mechanisms through which gut microbial communities may influence COVID-19 disease course. Further studies are needed to expand upon these observations to better leverage the gut microbiome as a potential biomarker for disease severity and as a target for therapeutic intervention.


Assuntos
COVID-19 , Microbioma Gastrointestinal , Microbiota , Humanos , Síndrome Pós-COVID-19 Aguda , Metagenoma
19.
J Appl Physiol (1985) ; 135(3): 500-507, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37439236

RESUMO

Management of acute respiratory distress syndrome (ARDS) is classically guided by protecting the injured lung and mitigating damage from mechanical ventilation. Yet the natural history of ARDS is also dictated by disruption in lung perfusion. Unfortunately, diagnosis and treatment are hampered by the lack of bedside perfusion monitoring. Electrical impedance tomography is a portable imaging technique that can estimate regional lung perfusion in experimental settings from the kinetic analysis of a bolus of an indicator with high conductivity. Hypertonic sodium chloride has been the standard indicator. However, hypertonic sodium chloride is often inaccessible in the hospital, limiting practical adoption. We investigated whether regional lung perfusion measured using electrical impedance tomography is comparable between indicators. Using a swine lung injury model, we determined regional lung perfusion (% of total perfusion) in five pigs, comparing 12% sodium chloride to 8.4% sodium bicarbonate across stages of lung injury and experimental conditions (body position, positive end-expiratory pressure). Regional lung perfusion for four lung regions was determined from maximum slope analysis of the indicator-based impedance signal. Estimates of regional lung perfusion between indicators were compared in the lung overall and within four lung regions. Regional lung perfusion estimated with a sodium bicarbonate indicator agreed with a hypertonic sodium chloride indicator overall (mean bias 0%, limits of agreement -8.43%, 8.43%) and within lung quadrants. The difference in regional lung perfusion between indicators did not change across experimental conditions. Sodium bicarbonate may be a comparable indicator to estimate regional lung perfusion using electrical impedance tomography.NEW & NOTEWORTHY Electrical impedance tomography is an emerging tool to measure regional lung perfusion using kinetic analysis of a conductive indicator. Hypertonic sodium chloride is the standard agent used. We measured regional lung perfusion using another indicator, comparing hypertonic sodium chloride to sodium bicarbonate in an experimental swine lung injury model. We found strong agreement between the two indicators. Sodium bicarbonate may be a comparable indicator to measure regional lung perfusion with electrical impedance tomography.


Assuntos
Lesão Pulmonar , Síndrome do Desconforto Respiratório , Suínos , Animais , Impedância Elétrica , Cinética , Bicarbonato de Sódio , Cloreto de Sódio , Pulmão/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Síndrome do Desconforto Respiratório/terapia , Perfusão , Tomografia/métodos
20.
Nitric Oxide ; 138-139: 17-25, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37277062

RESUMO

BACKGROUND: Several nitric oxide (NO) generating devices have been developed to deliver NO between 1 part per million (ppm) and 80 ppm. Although inhalation of high-dose NO may exert antimicrobial effects, the feasibility and safety of producing high-dose (more than 100 ppm) NO remains to be established. In the current study, we designed, developed, and tested three high-dose NO generating devices. METHODS: We constructed three NO generating devices: a double spark plug NO generator, a high-pressure single spark plug NO generator, and a gliding arc NO generator. The NO and NO2 concentrations were measured at different gas flows and under various atmospheric pressures. The double spark plug NO generator was designed to deliver gas through an oxygenator and mixing with pure oxygen. The high-pressure and gliding arc NO generators were used to deliver gas through a ventilator into artificial lungs to mimic delivering high-dose NO in the clinical settings. The energy consumption was measured and compared among the three NO generators. RESULTS: The double spark plug NO generator produced 200 ± 2 ppm (mean ± SD) of NO at gas flow of 8 L/min (or 320 ± 3 ppm at gas flow of 5 L/min) with electrode gap of 3 mm. The nitrogen dioxide (NO2) levels were below 3.0 ± 0.1 ppm when mixing with various volumes of pure oxygen. The addition of a second generator increased the delivered NO from 80 (with one spark plug) to 200 ppm. With the high-pressure chamber, the NO concentration reached 407 ± 3 ppm with continuous air flow at 5 L/min when employing the 3 mm electrode gap under 2.0 atmospheric pressure (ATA). When compared to 1 ATA, NO production was increased 22% at 1.5 ATA and 34% at 2 ATA. The NO level was 180 ± 1 ppm when connecting the device to a ventilator with a constant inspiratory airflow of 15 L/min, and NO2 levels were below 1 (0.93 ± 0.02) ppm. The gliding arc NO generator produced up to 180 ± 4 ppm of NO when connecting the device to a ventilator, and the NO2 level was below 1 (0.91 ± 0.02) ppm in all testing conditions. The gliding arc device required more power (in watts) to generate the same concentrations of NO when compared to double spark plug or high-pressure NO generators. CONCLUSIONS: Our results demonstrated that it is feasible to enhance NO production (more than 100 ppm) while maintaining NO2 level relatively low (less than 3 ppm) with the three recently developed NO generating devices. Future studies might include these novel designs to deliver high doses of inhaled NO as an antimicrobial used to treat upper and lower respiratory tract infections.


Assuntos
Óxido Nítrico , Dióxido de Nitrogênio , Terapia Respiratória , Pulmão , Administração por Inalação , Oxigênio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...